86159 1875 6640Project processing scheme: The project adopts the process of adsorption and desorption of zeolite molecular race + catalytic combustion (CO), organic waste gas is collected through the pipeline, and introduced into the dry filter to remove particles and harmful substances on the zeolite adsorption, and the organic waste gas is then sent to the molecular sieve after removal.
Project conditions: This project is to treat the organic waste gas generated by the paint mixing, dispersion, reaction, cleaning and other processes. The main components of the exhaust gas are ether, aliphatic benzene, toluene and xylene, malodorous substances and other volatile organic waste gas; exhaust gas treatment air volume of 30,000m3/h; the concentration of exhaust gas is about 300-400mg/m3; the highest value of 800mg/m3.
Project scale: air volume: 30000m3/h; equipment sets: 1 set;
Treatment process: dry filtration + zeolite molecular sieve adsorption and desorption + catalytic combustion (CO) process;
Project processing scheme: the project adopts zeolite molecular sieve adsorption and desorption + catalytic combustion (CO) process, organic waste gas is collected through the pipeline, introduced into the dry filter to remove particles and zeolite adsorption of hazardous substances, after removing the organic waste gas is then sent to the molecular sieve adsorption bed device, the VOCs component of the waste gas is absorbed by the zeolite, and then discharged into the atmosphere to meet the standards. When the adsorption bed is saturated by electric heating high temperature (120-280 ℃) desorption of VOCs substances, desorption of high concentrations of organic waste gas directly into the catalytic combustion co, through the accelerated oxidation of high concentrations of noble metals waste gas, in (300-380 ℃) high temperature purification and oxidation of harmless carbon dioxide (CO2) and water vapour (H20) and meet the standards of emission into the atmosphere.
Execution of governance standards: The treated waste gas emission meets the relevant local emission limit values;
Reason For Choice
Production plant area of more than 10,000 square feet, more than 100 people construction team.
A number of engineers and technicians, most of whom have more than 10 years of experience and have worked on numerous projects.
Adoption of the latest domestic and international treatment technology, with high treatment efficiency.
According to the actual needs of the project, free to customise the corresponding exhaust gas treatment solutions, all regions of the country package to meet the emission standards.
Passed the third level of construction enterprise qualification and a number of technical patents...
1000+ project experience, more than 100 industry partners, complete environmental protection qualification.
Contact - Ways
Contact informationCatalytic combustion machine is a dry filter + adsorption de...
Activated carbon adsorption and desorption + CO catalytic co...
Zeolite rotor concentration + RTO regenerative incinerator c...
Zeolite rotor concentration + CO catalytic combustion proces...
CO catalytic combustion + TO direct combustion furnace proce...
For low concentration and low air volume of waste gas treatm...
Project conditions: This project is to treat the organic waste gas generated by the paint mixing, dispersion, reaction, cleaning and other processes. The main components of the exhaust gas are ether, aliphatic benzene, toluene and xylene, malodorous substances and other volatile organic waste gas; exhaust gas treatment air volume of 30,000m3/h; the concentration of exhaust gas is about 300-400mg/m3; the highest value of 800mg/m3.
Project scale: air volume: 30000m3/h; equipment sets: 1 set;
Treatment process: dry filtration + zeolite molecular sieve adsorption and desorption + catalytic combustion (CO) process;
Project processing scheme: the project adopts zeolite molecular sieve adsorption and desorption + catalytic combustion (CO) process, organic waste gas is collected through the pipeline, introduced into the dry filter to remove particles and zeolite adsorption of hazardous substances, after removing the organic waste gas is then sent to the molecular sieve adsorption bed device, the VOCs component of the waste gas is absorbed by the zeolite, and then discharged into the atmosphere to meet the standards. When the adsorption bed is saturated by electric heating high temperature (120-280 ℃) desorption of VOCs substances, desorption of high concentrations of organic waste gas directly into the catalytic combustion co, through the accelerated oxidation of high concentrations of noble metals waste gas, in (300-380 ℃) high temperature purification and oxidation of harmless carbon dioxide (CO2) and water vapour (H20) and meet the standards of emission into the atmosphere.
Execution of governance standards: The treated waste gas emission meets the relevant local emission limit values;